Pengaruh Automatic Change Over Switch Terhadap Peningkatan Keandalan Gardu Distribusi T3-200A/1 Penyulang PLR-04

Authors

  • Tri Irianto Tjendrowasono Universitas Surakarta
  • Supriyana Nugroho Universitas Surakarta
  • Ni Kadek Devi Suyastini Universitas Surakarta

DOI:

https://doi.org/10.56795/fortech.v4i2.4205

Keywords:

Reliability, SAIDI, SAIFI, Automatic Change Over Switch, ACOS

Abstract

The process of distributing electrical energy has the potential to cause disturbances that can occur due to natural disturbances, disturbances to electrical equipment, disturbances at the generating center, transmission lines, and disturbances in the distribution network that can disrupt the reliability and service quality of the distribution of electrical energy. The quality of reliability can be rated by the length of outages, which can be determined using the System Average Interruption Duration Index (SAIDI), and how often blackouts occur in one unit of time, which can be determined using the System Average Interruption Frequency Index (SAIFI). In maintaining the reliability of electrical energy, additional equipment is needed that is capable of supplying backup energy to the load when a disturbance occurs, namely the Automatic Change Over Switch (ACOS). ACOS is a device that works automatically for the process of maneuvering the network from two voltage sources to maintain electricity availability without having to have long blackouts due to disturbances or loss of voltage at the main source. The use of the Automatic Change Over Switch (ACOS) is proven to be able to increase the reliability of electrical energy at distribution substation T3-200A/1 feeder PLR-04 by reducing the length of time outages (SAIDI) and reducing the frequency, because customers don't feel outages when the disturbance occurs. In addition, the use of Automatic Change Over Switch (ACOS) can also reduce the energy not supplied (ENS)

References

M. Ali, R. Rukslin, H. Nurohmah, Y. Arie Pambayun, and A. Zaini, “Rekonfigurasi Jaringan Distribusi Radial Di Penyulang Purwoasri Berbasis Modified Imperialist Competitive Algorithms (MICA),” J. FORTECH, vol. 1, no. 2, pp. 74–78, Aug. 2020, doi: 10.32492/fortech.v1i2.227.

C. Onah, P. Kpochi, and A. Goodman, “Design and Implementation of an Automatic Changeover Switch with Generator Trip-off Mechanism,” Int. J. Eng. Sci. Invent., vol. 9, no. 7, pp. 41–48, 2020.

I. Pratama, Y. Mohammad, and T. I. Yusuf, “Analisis Keandalan Jaringan Distribusi 20kV Pada ULP Toili Berdasarkan SAIDI dan SAIFI,” Jambura J. Electr. Electron. Eng., vol. 5, no. 2, pp. 197–203, 2023, doi: 10.37905/jjeee.v5i2.18145.

Titiek Suheta and Muhammad Faisal A, “Analisa Keandalan Sistem Jaringan Distribusi 20 kV Dan Rekonfigurasi Recloser Pada Penyulang Kamal,” J. JEETech, vol. 3, no. 2, pp. 64–70, Sep. 2022, doi: 10.48056/jeetech.v3i2.196.

Machrus Ali, Dwi Ajiatmo, and Muhlasin, “Optimasi Kualitas Tenaga Listrik Di Area Banyuwangi Menggunakan Radio Gateway Over Internet Protocol,” J. JEETech, vol. 1, no. 2, pp. 70–77, Nov. 2020, doi: 10.48056/jeetech.v1i2.3.

M. Choiruddin, Choiruddin; Ridhwan, Fauzi, Ahmad; Muhlasin, Muhlasin; Nurohmah, Hidayatul; Ali, “Rekonfigurasi Jaringan Distribusi Tenaga Listrik Penyulang Benteng Berbasis MICA,” SinarFe7, vol. 1, no. 1, pp. 112–116, 2018.

Prastiyo, M.E.E. “Pengaruh Penggunaan Kubikel Automatic Change Over (ACO) di Gardu Distribusi CSU 105 dan Gardu Distribusi KLD 58 pada Jaringan Distribusi Unit Pelaksana Pengatur Distribusi (UP2D) Banten”, 2020

Rasmini, N.W. “Panel Automatic Transfer Switch (ATS) - Automatic Main Failure (AMF) di Perumahan Direksi BTDC” Jurnal Logic, Vol. 13, No. 1, pp 16-21, 2013.

Widiarto, Hendro, Samanhudi, A. “Transmisi dan Distribusi” Edited by Y. M. Hidayat; Miskadi; Setiawan. Pusat Pengembangan Pendidikan dan Penelitian Indonesia, 2022

I Kadek Hery Samudra, I Gede Dyana Arjana, I Wayan Artha Wijaya “Evaluasi Peningkatan Mutu Pelayanan dan Keandalan pada Penyulang Cimpaeun PLN UP3 Depok menggunakan Load Break Switch (LBS) Three Way”, Teknologi Elektro, Vol. q5, No. 1, pp 48-55. 2013.

Ujang Wiharja, Abdul Kodir, “Optimalisasi Automatic Change Over (ACO) untuk Pelanggan Premium PT PLN UP3 Bulungan”, Teknokris, Vol. 26, No. 1, pp 1-8, 2023.

Downloads

Published

2023-12-29

How to Cite

Irianto Tjendrowasono, T., Nugroho, S. ., & Kadek Devi Suyastini , N. . (2023). Pengaruh Automatic Change Over Switch Terhadap Peningkatan Keandalan Gardu Distribusi T3-200A/1 Penyulang PLR-04 . Jurnal FORTECH, 4(2), 99–105. https://doi.org/10.56795/fortech.v4i2.4205